Dual Junction Coaxial Isolator 200 ~ 1875MHz

Application

RF power amplifier protection.

Digital, Satellite, Mobile Communication.

Medical, Communication, Security.

Military, Space and Commercial applications.


RF Characteristics

Part Number

Frequency Range
   (MHz)

Isolation
  Min(dB)

VSWR
  Max

Insertion Loss
  Max(dB)

Connector

Type

Temp.(°C)

5o0270380220240

220 ~ 240

36

1.3

1.3

TAB

-20 ~ +65

5o0270380240260

240 ~ 260

36

1.3

1.0

TAB

-20 ~ +65

5o0270380260280

260 ~ 280

40

1.25

1.0

TAB

-20 ~ +65

5o0270380309339

309 ~ 339

40

1.25

0.8

TAB

-20 ~ +65

5o0270380350370

350 ~ 370

42

1.2

0.7

TAB

-20 ~ +65

5o0270380380460

380 ~ 460

36

1.3

1.0

TAB

-20 ~ +65

5o0270380390410

390 ~ 410

46

1.2

0.6

TAB

-30 ~ +70

5o0270380400470

400 ~ 470

40

1.25

0.8

TAB

-30 ~ +70

5o0270380413419

413 ~ 419

60

1.15

0.6

TAB

-30 ~ +70

5o0270380413419

413 ~ 419

60

1.15

0.6

TAB

-30 ~ +70

5o0270380419425

419 ~ 425

60

1.15

0.6

TAB

-30 ~ +70

5o0270380450520

450 ~ 520

40

1.25

0.8

TAB

-20 ~ +65

5o0270380600800

600 ~ 800

38

1.25

1.0

TAB

-20 ~ +65

5o0270380700900

700 ~ 900

40

1.25

0.8

TAB

-30 ~ +70

5o02703807001000

700 ~ 1000

32

1.4

1.2

TAB

-20 ~ +65

5o0270380770860

770 ~ 860

46

1.2

0.6

TAB

-30 ~ +70

5o0270380860872

860 ~ 872

60

1.15

0.5

TAB

-20 ~ +65

5o0270380900930

900 ~ 930

60

1.15

0.4

TAB

-40 ~ +85

5o027038010001300

1000 ~ 1300

40

1.25

0.8

TAB

-30 ~ +70

5o027038010001700

1000 ~ 1700

30

1.45

1.0

TAB

-30 ~ +70

5o027038012961298

1296 ~ 1298

50

1.15

0.6

TAB

-40 ~ +85

Basic Specifications

Dimension

70*38*11mm

Forward   Power

300W

Reverse   Power

30W

Connector   Type

TAB

Storage Temperature

-55℃~+125℃

Impedance

50Ω

Overall Dimension(mm, Tolerances: ±2% unless otherwise stated.)

5o0270380.png

Instructions                             

It can be dual junction or multiple for high isolation.

◆Installing the embedded isolator/circulator, please use stainless steel or brass screws.

◆Only some common frequencies in the table can be produced according to the user's requirements.

◆It supports a one-year standard warranty.