Dual Junction Drop in Isolator 400 ~3000MHz

Application

RF power amplifier protection.

Digital, Satellite, Mobile Communication.

Medical, Communication, Security.

Military, Space and Commercial applications.

 

RF Characteristics

Part Number

Frequency Range
   (MHz)

Isolation
  Min(dB)

VSWR
  Max

Insertion Loss
  Max(dB)

Forward Power(W)

Reverse Power(W)

5o0240270400420

400 ~ 420

32

1.4

1.4

100

100

5o0240270430450

430 ~ 450

36

1.3

1.0

100

100

5o0240270450470

450 ~ 470

40

1.25

1.0

100

100

5o0240270470490

470 ~ 490

40

1.25

1.0

100

100

5o0240270490510

490 ~ 510

40

1.25

1.0

100

100

5o0240270700800

700 ~ 800

36

1.3

1.0

100

100

5o0240270825865

825 ~ 865

40

1.25

0.7

100

100

5o0240270860960

860 ~ 960

40

1.25

0.8

100

100

5o0240270869894

869 ~ 894

45

1.2

0.6

100

100

5o0240270880960

880 ~ 960

45

1.2

0.6

100

100

5o0240270902928

902 ~ 928

45

1.15

0.5

100

100

5o0240270925960

925 ~ 960

45

1.15

0.5

100

100

5o024027010001200

1000 ~ 1200

40

1.25

0.8

100

100

5o024027014501550

1450 ~ 1550

45

1.2

0.6

100

100

5o024027017102170

1710 ~ 2170

36

1.3

1.0

100

100

5o024027017151805A30

1715 ~ 1805

45

1.2

0.6

100

30dB 100W

5o024027018051880A30

1805 ~ 1880

50

1.15

0.5

100

30dB 100W

5o024027019201990A30

1920 ~ 1990

50

1.15

0.5

100

30dB 100W

5o024027021102170

2110 ~ 2170

50

1.15

0.5

100

100

5o024027020002700

2000 ~ 2700

36

1.3

1.0

100

100

5o024027022000200

2200 ~ 2300

45

1.2

0.6

100

100

5o024027024002500

2400 ~ 2500

45

1.2

0.6

100

100

5o024027024962690

2496 ~ 2690

45

1.2

0.6

100

100

5o024027025002700

2500 ~ 2700

45

1.2

0.6

100

100

Basic Specifications

Dimension

40*27.5*8.6mm

Connector   Type

TAB

Operating Temperature

-40 ~ +85℃

Storage Temperature

-55℃ ~ +125℃

Impedance

50Ω

Overall Dimension(mm, Tolerances: ±2% unless otherwise stated.)

5o0240270.png

Instructions                             

It can be dual junction or multiple for high isolation.

◆For the third stage, you can select a 100W load, a 20dB attenuator, or a 30dB attenuator.

◆Installing the embedded isolator/circulator, please use stainless steel or brass screws.

◆Only some common frequencies in the table can be produced according to the user's requirements.

◆It supports a one-year standard warranty.